Catalog
|
I 1.5-40 I UHL2
|
Insulator unit of this type complies with Specs (TU) 3493-175-00111120-2002 requirements. |
|
Voltage
|
-One-minute 50 Hz test voltage
|
kВ
|
24
|
|
-50 Hz test voltage under dew
|
kВ
|
12
|
|
-50 Hz test voltage under hoarfrost
|
kВ
|
3.6
|
|
Withstand voltage
|
-Puncture voltage
|
kВ
|
45
|
|
-Impulse test voltage
|
full impulse
|
kВ
|
40
|
|
chopped imppulse
|
kВ
|
50
|
|
-50 Hz withstand voltage (dry)
|
kВ
|
40
|
|
Mechanical failing load (beding), minimum
|
kН
|
1.5
|
|
Mechanical failing tensile load, minimum
|
kН
|
2.5
|
|
Weight, maximum
|
kg
|
0.33
|
|
|
|
|
|
IOR -10-7.50 III UHL, Т2
|
Insulator unit of this type complies with Specs (TU) 34-27-90-93 requirements. |
|
Minimum voltage
|
Puncture voltage |
kV
|
80
|
| One-minute 50 Hz test voltage |
kV
|
42
|
| Dry withstand 50 Hz voltage (with smooth rise) |
kV
|
47
|
| Impulse test voltage |
full impulse |
kV
|
75
|
| chopped impulse |
kV
|
90
|
| 50 Hz test voltage under dew |
kV
|
28
|
| 50 Hz test voltage under hoarfrost |
kV
|
12
|
| Creepage distance, minimum |
mm
|
175
|
| Mechanical failing load (bending), minimum |
kN
|
7.5
|
| Weight, maximum |
kg
|
2.35
|
|
|
|
|
|
ITG 8-80 1
|
|
Minimum voltage |
Puncture voltage |
kV |
80 |
| One-minute 50 Hz test voltage |
kV |
42 |
| Dry withstand 50 Hz voltage (with smooth rise) |
kV |
47 |
| Impulse test voltage |
full impulse |
kV |
75 |
| chopped impulse |
kV |
90 |
| Mechanical failing tensile load, minimum |
kH |
80 |
| Average annual rate of failure |
1/h |
1x10-7 |
| Weight, maximum |
kg |
0,81 |
|
|
|
|
|
IO-1А
|
Insulator unit of this type complies with Specs (TU) 3493-00111120-99 requirements.
|
|
Voltage
|
| 50 Hz withstand voltage (Dry) |
kV
|
40
|
| Nominal voltage (recomended) |
kV
|
6
|
|
|
|
|
|
I 8-80 IV UHL2, T2
|
Insulator unit of this type complies with Specs (TU) 3493-174-00111120-02 requirements.
|
|
Voltage
|
-One-minute 50 Hz test voltage
|
kV
|
42
|
|
-50 Hz test voltage under dew
|
kV
|
28
|
|
-50 Hz test voltage under hoarfrost
|
kV
|
12
|
|
Withstand voltage
|
-Puncture voltage
|
kV
|
80
|
|
-Impulse test voltage
|
full impulse
|
kV
|
75
|
|
chopped imppulse
|
kV
|
90
|
|
-50 Hz withstand voltage (dry)
|
kV
|
80
|
|
Mechanical failing load (bending), minimum
|
kN
|
8.0
|
|
Weight, maximum
|
kg
|
2.25
|
|
|
|
|
|
I 4-80 II UHL2, T2
|
Insulator unit of this type complies with Specs (TU) 3493-173-00111120-2002 requirements |
|
Voltage
|
-One-minute 50 Hz test voltage
|
kV
|
42
|
|
-50 Hz test voltage under dew
|
kV
|
28
|
|
-50 Hz test voltage under hoarfrost
|
kV
|
12
|
|
Withstand voltage
|
-Puncture voltage
|
kV
|
80
|
|
-Impulse test voltage
|
full impulse
|
kV
|
75
|
|
chopped imppulse
|
kV
|
90
|
|
-50 Hz withstand voltage (dry)
|
kV
|
80
|
|
Mechanical failing load (bending), minimum
|
kN
|
4
|
|
Weight, maximum
|
kg
|
1.6
|
|
|
|
|
|
ITG 8-80
|
Insulator meet TU 3493-178-00111120-2003 requirements. |
Minimum voltage |
Puncture voltage |
kV |
80 |
| One-minute 50 Hz test voltage |
kV |
42 |
| Dry withstand 50 Hz voltage (with smooth rise) |
kV |
47 |
| Impulse test voltage |
full impulse |
kV |
75 |
| chopped impulse |
kV |
90 |
| Mechanical failing tensile load, minimum |
kH |
80 |
| Average annual rate of failure |
1/h |
1x10-7 |
| Weight, maximum |
kg |
0,81 |
|
|
|
|
|
I4-80 I
|
Insulator meet TU 3493-173-00111120-2002 requirements. |
|
Voltage
|
-One-minute 50 Hz test voltage
|
kV
|
42
|
|
-50 Hz test voltage under dew
|
kV
|
28
|
|
-50 Hz test voltage under hoarfrost
|
kV
|
12
|
|
Withstand voltage
|
-Puncture voltage
|
kV
|
80
|
|
-Impulse test voltage
|
full impulse
|
kV
|
75
|
|
chopped imppulse
|
kV
|
90
|
|
-50 Hz withstand voltage (dry)
|
kV
|
80
|
|
Mechanical failing load (bending), minimum
|
kN
|
4
|
|
Weight, maximum
|
kg
|
1.6
|
|
|
|
|
|
|
|
 |